Dental Implant (WP) D 4.75 mm L 13 mm

Brand Name : Frontier

Model Name / Code : 1022KDAOF3625

Manufacturer : ilerimplant group

Compare

EGP1,300.00

Sold By : gmiegypt
No ratings found yet!
Contact Vendor

Product Description

gmi frontier internal connection hexagonal implants are machined in c.p.
grade IV titanium of the highest quality, thus ensuring a high chemical
stability and excellent biocompatibility. The titanium oxide layer, that
is formed on the implant surface after the passivation process, and
the careful design of the outer surface of the thread, guarantee good
osseointegration and high stability.
The external dual inlet thread of the implant helps to reduce surgery time.
Moreover, the rounded shapes, self-threading millings and slight tapering
facilitate implant insertion, reducing tension at the bone-implant
interface and thus preventing threading stress-related problems.

Item Name Dental Implant (WP) D 4.75 mm L 13 mm
Brand Name Frontier
Model Name / Code 1022KDAOF3625
Manufacturer ilerimplant group
Country of origin Spain
Technical Specifications Implant Line: Bone Level Implant / Raw Material: Pure Titanium Grade 4 / Connection: Internal Hexagon / Surface Treatment: Advanced Double-Grip Surface With Titanium Oxide Layer / Inlet Thread: Dual Thread / Cortical Thread: Quartable Thread / Self threading millings: 3 millings at 120º Atraumatic tip / Internal hexagon: B/F 2.45 mm x 1.50 mm / Internal thread: M1.8 x 0.35 mm / Platform: Wide / Diameter: 4.75 mm / Lenght: 13 mm
Package 1 Screen-printed cardboard box with double packaging containing the implant system (implant & cover screw).
Variations The double packaging consists of secondary packaging made of technical plastic and the primary packaging made of Pyrex glass to ensure the inert performance of the container which sterilized with gamma radiation according to regulations.The primary packaging contains a titanium support which only houses the dental implant, prepared to be inserted directly into the mouth, using implant carrier wrench.This packaging gives more control and a better view of the implant insertion process, it is easier to use in reduced interdental spaces and a reduction in surgery time.
Manufacture Date
Expiry Date
Guarantee terms Life Time
Remarks Recommended for molars with tightening torque of 35-40 N.cm and max. tightening of 60 N.cm and for the cover screw recommended with max. torque 15 N.cm

Vendor Information

Frontier
1008KDAOF3609
ilerimplant group
(0)

gmi frontier internal connection hexagonal implants are machined in c.p. grade IV titanium of the highest quality, thus ensuring a high chemical stability and excellent biocompatibility. The titanium oxide layer, that is formed on the implant surface after the passivation process, and the careful design of the outer surface of the thread, guarantee good osseointegration …
Continue reading Dental Implant (RP) D 3.75 mm L 13 mm

Frontier
1065KDHOF3601
ilerimplant group
(0)

When it is necessary to perform a provisional restoration while the boneimplant interfases or the soft tissues are healing, the temporary cylinder is used, defined as technical plastic machined attachment that once attached to the crown of the implant with clinic screw, will absorb most of the masticatory stresses while avoiding overloading the implant while …
Continue reading Dental Temporary Cylinder (RP)(non-rotary)

Frontier
1089KDPOF0035
ilerimplant group
(0)

Once the repair phase of the tissue supporting the implant has finished, in the case of implants fully or partially covered by soft tissue there must be a mucosal channel or tunnel enabling connection of the implant to the prosthesis or secondary structure. Healing abutments are used to form the mucosal route, once the soft …
Continue reading Dental Multi-esthetic Healing cap (RP)

Frontier
1110KDCOF3613
ilerimplant group
(0)

To replace a dental crown with a restoration dental prosthesis, a castable is used, which is defined as a meltable plastic machined attachment that, once positioned over the coronal part of the internal connection implant, will be the initial basis to model the form of the final structure, to be cast in the corresponding metal.

Frontier
1023KDAOF3632
ilerimplant group
(0)

gmi frontier internal connection hexagonal implants are machined in c.p. grade IV titanium of the highest quality, thus ensuring a high chemical stability and excellent biocompatibility. The titanium oxide layer, that is formed on the implant surface after the passivation process, and the careful design of the outer surface of the thread, guarantee good osseointegration …
Continue reading Dental Implant (WP) D 5.75 mm L 6.5 mm

Frontier
1105KDSOF3606
ilerimplant group
(0)

Impression coping are defined as the machined attachments that, connecting to the coronal part of the implant within the oral cavity and axially fixed by the impression screw, are used to make the transfer of the position of the implant in the biological medium to a laboratory model, on which the prosthetic will work to …
Continue reading Dental Clothed Tray impression coping (RP)

Product Enquiry