gmi frontier internal connection hexagonal implants are machined in c.p.
grade IV titanium of the highest quality, thus ensuring a high chemical
stability and excellent biocompatibility. The titanium oxide layer, that
is formed on the implant surface after the passivation process, and
the careful design of the outer surface of the thread, guarantee good
osseointegration and high stability.
The external dual inlet thread of the implant helps to reduce surgery time.
Moreover, the rounded shapes, self-threading millings and slight tapering
facilitate implant insertion, reducing tension at the bone-implant
interface and thus preventing threading stress-related problems.

Item Name Dental Implant (WP) D 4.75 mm L 6.5 mm
Brand Name Frontier
Model Name / Code 1018KDAOF3631
Manufacturer ilerimplant group
Country of origin Spain
Technical Specifications Implant Line: Bone Level Implant / Raw Material: Pure Titanium Grade 4 / Connection: Internal Hexagon / Surface Treatment: Advanced Double-Grip Surface With Titanium Oxide Layer / Inlet Thread: Dual Thread / Cortical Thread: Quartable Thread / Self threading millings: 3 millings at 120º Atraumatic tip / Internal hexagon: B/F 2.45 mm x 1.50 mm / Internal thread: M1.8 x 0.35 mm / Platform: Wide / Diameter: 4.75 mm / Lenght: 6.5 mm
Package 1 Screen-printed cardboard box with double packaging containing the implant system (implant & cover screw).
Variations The double packaging consists of secondary packaging made of technical plastic and the primary packaging made of Pyrex glass to ensure the inert performance of the container which sterilized with gamma radiation according to regulations.The primary packaging contains a titanium support which only houses the dental implant, prepared to be inserted directly into the mouth, using implant carrier wrench.This packaging gives more control and a better view of the implant insertion process, it is easier to use in reduced interdental spaces and a reduction in surgery time.
Manufacture Date
Expiry Date
Guarantee terms Life Time
Remarks Recommended for molars with tightening torque of 35-40 N.cm and max. tightening of 60 N.cm and for the cover screw recommended with max. torque 15 N.cm

Vendor Information

Frontier
1049KDMOF3612
ilerimplant group
(0)

When it is necessary to correct an extreme angular position of the implant inside the bone structure in relation to adjacent natural or prosthetic teeth, angled abutments should be used. Once mounted and oriented on the implant, these abutments will allow the parallelization of the new crown with other structures.Grade V titanium machining as per …
Continue reading Dental Esthetic angeled abutment (WP) 20°

Frontier
1009KDAOF3610
ilerimplant group
(0)

gmi frontier internal connection hexagonal implants are machined in c.p. grade IV titanium of the highest quality, thus ensuring a high chemical stability and excellent biocompatibility. The titanium oxide layer, that is formed on the implant surface after the passivation process, and the careful design of the outer surface of the thread, guarantee good osseointegration …
Continue reading Dental Implant (RP) D 3.75 mm L 15 mm

Frontier
1108KDCOF3611
ilerimplant group
(0)

To replace a dental crown with a restoration dental prosthesis, a castable is used, which is defined as a meltable plastic machined attachment that, once positioned over the coronal part of the internal connection implant, will be the initial basis to model the form of the final structure, to be cast in the corresponding metal.

Frontier
1015KDAOF3615
ilerimplant group
(0)

gmi frontier internal connection hexagonal implants are machined in c.p. grade IV titanium of the highest quality, thus ensuring a high chemical stability and excellent biocompatibility. The titanium oxide layer, that is formed on the implant surface after the passivation process, and the careful design of the outer surface of the thread, guarantee good osseointegration …
Continue reading Dental Implant (RP) D 4.25 mm L 13 mm

Frontier
1029KDPOC3602
ilerimplant group
(0)

Once the repair phase of the tissue supporting the implant has finished, in the case of implants fully or partially covered by soft tissue there must be a mucosal channel or tunnel enabling connection of the implant to the prosthesis or secondary structure. Healing abutments are used to form the mucosal route, once the soft …
Continue reading Dental Healing abutment (RP)(cylinderical) h 3 mm

Frontier
1032KDPOC3605
ilerimplant group
(0)

Once the repair phase of the tissue supporting the implant has finished, in the case of implants fully or partially covered by soft tissue there must be a mucosal channel or tunnel enabling connection of the implant to the prosthesis or secondary structure. Healing abutments are used to form the mucosal route, once the soft …
Continue reading Dental Healing abutment (WP)(cylinderical) h 2 mm

Product Enquiry